Výňatek z katalogového listu: Technická data   NJ2-12GK-N

General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance2 mm
Installationflush
Assured operating distance0 ... 1.62 mm
Reduction factor rAl 0.4
Reduction factor rCu 0.3
Reduction factor r304 0.85
Output type2-wire
Nominal ratings
Nominal voltage8.2 V (Ri approx. 1 kΩ)
Switching frequency0 ... 2000 Hz
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
Current consumption
Measuring plate not detectedmin. 3 mA
Measuring plate detected≤ 1 mA
Functional safety related parameters
Safety Integrity Level (SIL)SIL 2
MTTFd5887 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
StandardsEN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
IECEx approval
Equipment protection level GbIECEx PTB 11.0037X
Equipment protection level DaIECEx PTB 11.0037X
Equipment protection level MbIECEx PTB 11.0037X
ATEX approval
Equipment protection level GbPTB 00 ATEX 2048 X
Equipment protection level DaPTB 00 ATEX 2048 X
UL approvalcULus Listed, General Purpose
CCC approval
Hazardous Location2020322315002255
NEPSI approval
NEPSI certificateGYJ16.1393X
CML approvalon request
ANZEx18.3018X
KCC approval
Hazardous Location19-AV4BO-0227
Marine approvalDNVGL TAA00001A5
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Mechanical specifications
Connection typecable
Housing materialPBT
Sensing facePBT
Degree of protectionIP66 / IP68
Cable
Cable diameter4.8 mm ± 0.2 mm
Bending radius> 10 x cable diameter
MaterialPVC
Core cross section0.34 mm2
Length2 m
Dimensions
Length35 mm
Diameter12 mm
General information
Use in the hazardous areasee instruction manuals

Classifications

SystemClasscode
ECLASS 13.027274001
ECLASS 12.027274001
ECLASS 11.027270101
ECLASS 10.0.127270101
ECLASS 9.027270101
ECLASS 8.027270101
ECLASS 5.127270101
ETIM 9.0EC002714
ETIM 8.0EC002714
ETIM 7.0EC002714
ETIM 6.0EC002714
ETIM 5.0EC002714
UNSPSC 12.139121550

Details: NJ2-12GK-N

Datasheet: NJ2-12GK-N

DatasheetTyp souboruVelikost souboru
Datasheet NJ2-12GK-NPDF496 KB
Datasheet NJ2-12GK-NPDF493 KB
Fiche de données NJ2-12GK-NPDF493 KB
Datenblatt NJ2-12GK-NPDF493 KB
Scheda tecnica NJ2-12GK-NPDF492 KB
Datasheet NJ2-12GK-NPDF498 KB
Folha de dados NJ2-12GK-NPDF494 KB
Hoja de datos NJ2-12GK-NPDF493 KB
Datasheet NJ2-12GK-NPDF506 KB

Documents: NJ2-12GK-N

Instruction manualsTyp souboruVelikost souboru
ИнструкцииPDF185 KB
Návod k poużitíPDF177 KB
Instruktions manualPDF175 KB
Instruction manualPDF177 KB
KasutusjuhendPDF171 KB
KäyttöohjePDF170 KB
Manuel d'instructionsPDF179 KB
BetriebsanleitungPDF177 KB
Οδηγίες χρήσηςPDF187 KB
HandleidingPDF177 KB
Instruction manual / BetriebsanleitungPDF175 KB
Használati útmutatóPDF179 KB
Manuale di istruzioniPDF177 KB
Lietošanas pamācībaPDF176 KB
Instrukciju vadovasPDF177 KB
Instrukcja obsługiPDF178 KB
Manual de instruçõesPDF179 KB
Manual de utilizarePDF179 KB
Návod na poużitiePDF178 KB
Navodila za uporaboPDF175 KB
Manual de instruccionesPDF179 KB
ManualPDF175 KB
Technical information
Installation conditionsPDF1054 KB
EinbaubedingungenPDF1060 KB

CAD+CAE: NJ2-12GK-N

CADTyp souboruVelikost souboru
CAD 3-D / CAD 3-DSTP51 KB
CAD Portal / CAD PortalLINK---
EPLAN
CAE EPLAN Data Portal / CAE EPLAN Data PortalLINK---
EPLAN macro EDZ / EPLAN Makro EDZEDZ61 KB

Související produkty: NJ2-12GK-N

Accessories

Mounting flange, 12 mmfa

Our amplify article gives interesting insights about the development of the new, modern portfolio of inductive proximity sensors from Pepperl+Fuchs. Get the whole story here! 

 

 

Knowledge Base for Inductive Sensors

The knowledge base for inductive sensors contains extensive expertise and supports you in the highly precise and smooth operation of the sensors in your machinery and plants.

VariKont s technologií aktivního stínění

Indukční snímače VariKont s technologií aktivního stínění poskytují dlouhé spínací vzdálenosti bez ohledu na instalační situaci a okolní materiál. Profitujte z jednoduššího návrhu zařízení a snížených nákladů.

Indukční bezpečnostní senzory SIL 2 PL d

Vzhledem k tomu, že indukční bezpečnostní senzory SIL 2 / PL d nemají pásmo necitlivosti, může přenos dat probíhat bez zachování jakékoli minimální vzdálenosti mezi senzorem a cílem. Seznamte se s optimalizovaným portfoliem pro náročná prostředí.