Servisní linka pro průmyslové snímače
Servisní linka ochrany před výbuchem

Inductive sensor NCN3-F31K-N5-K

NCN3-F31K-N5-K
  • Direct mounting on standard actuators
  • Fixed setting
  • 2:1 transfer method
  • LEDs for switching state of sensor and solenoid valve
  • Valve LEDs disconnectable
  • ATEX & IECEX certifications


NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below:

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Výňatek z katalogového listu: Technická data   NCN3-F31K-N5-K

General specifications
Switching function2 x normally closed (NC)
Output typeNAMUR
Rated operating distance3 mm
Installationflush mountable
Assured operating distance0 ... 2.4 mm
Actual operating distance2.7 ... 3.3 mm typ.
Reduction factor rAl 0.35
Reduction factor rCu 0.3
Reduction factor r304 0.75
Reduction factor rSt37 1
Reduction factor rBrass 0.45
Output type2-wire
Nominal ratings
Nominal voltage8.2 V (Ri approx. 1 kΩ)
Switching frequency0 ... 3 kHz
Hysteresistyp. 5 %
Short-circuit protectionyes
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
Current consumption
Measuring plate not detected≥ 3 mA
Measuring plate detected≤ 1 mA
Time delay before availability≤ 1.1 ms
Switching state indicatorLED, yellow
Valve status indicatorLED, yellow
Functional safety related parameters
MTTFd1470 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Valve circuit
Voltagemax. 32 V DC
Currentmax. 240 mA
Short-circuit protectionno
Reverse polarity protectionyes, with reversed output LED is out of function, therfore more power for solenoid valve
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
Electromagnetic compatibilityNE 21:2007
StandardsEN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
IECEx approval
Equipment protection level GaIECEx TUN 17.0021X
Equipment protection level GbIECEx TUN 17.0021X
Equipment protection level MbIECEx TUN 17.0021X
ATEX approval
Equipment protection level GaTÜV 99 ATEX 1479 X
Equipment protection level GbTÜV 99 ATEX 1479 X
Equipment protection level Gc (ic)PF13CERT2895 X
UL approvalcULus Listed, General Purpose
Ordinary LocationE87056
Hazardous LocationE501628
Control drawing116-0456
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection (system side)Cage tension spring terminals
Stripped length 7 mm
M20 x 1.5 cable gland
usable thread length 11.5 mm
screw-in depth max. 11.5 mm
Core cross section (system side)1.5/2.5 mm2 flexible/rigid
Connection (valve side)Cage tension spring terminals
Core cross section (valve side)1.5/2.5 mm2 flexible/rigid
Housing materialPBT
Sensing facePBT
Degree of protectionIP67
Tightening torque, fastening screws4 Nm ... 5 Nm
Tightening torque, housing screws1 Nm
Tightening torque, cable glandM20 x 1.5 ; max. 7 Nm
M12 x 1.5 ; max. 1.5 Nm
Dimensions
Height35.5 mm
Width65 mm
Length77.5 mm
NoteLED switch-off
General information
Use in the hazardous areasee instruction manuals

Classifications

SystemClasscode
ECLASS 13.027273901
ECLASS 12.027273901
ECLASS 11.027220501
ECLASS 10.0.127220501
ECLASS 9.027220501
ECLASS 8.027220501
ECLASS 5.127220501
ETIM 9.0EC002714
ETIM 8.0EC002714
ETIM 7.0EC002714
ETIM 6.0EC002714
ETIM 5.0EC002714
UNSPSC 12.139121550

Details: NCN3-F31K-N5-K

Datasheet: NCN3-F31K-N5-K

DatasheetTyp souboruVelikost souboru
Datasheet NCN3-F31K-N5-KPDF890 KB
Datasheet NCN3-F31K-N5-KPDF883 KB
Fiche de données NCN3-F31K-N5-KPDF887 KB
Datenblatt NCN3-F31K-N5-KPDF885 KB
Scheda tecnica NCN3-F31K-N5-KPDF888 KB
Datasheet NCN3-F31K-N5-KPDF889 KB
Folha de dados NCN3-F31K-N5-KPDF884 KB
Hoja de datos NCN3-F31K-N5-KPDF887 KB
Datasheet NCN3-F31K-N5-KPDF899 KB

Documents: NCN3-F31K-N5-K

Instruction manualsTyp souboruVelikost souboru
ИнструкцииPDF196 KB
Návod k poużitíPDF187 KB
Instruktions manualPDF185 KB
Instruction manualPDF187 KB
KasutusjuhendPDF180 KB
KäyttöohjePDF179 KB
Manuel d'instructionsPDF192 KB
BetriebsanleitungPDF188 KB
Οδηγίες χρήσηςPDF199 KB
HandleidingPDF188 KB
Instruction manual / BetriebsanleitungPDF184 KB
Használati útmutatóPDF190 KB
Manuale di istruzioniPDF189 KB
Lietošanas pamācībaPDF186 KB
Instrukciju vadovasPDF187 KB
Instrukcja obsługiPDF189 KB
Manual de instruçõesPDF191 KB
Manual de utilizarePDF191 KB
Návod na poużitiePDF188 KB
Navodila za uporaboPDF184 KB
Manual de instruccionesPDF191 KB
ManualPDF184 KB

CAD+CAE: NCN3-F31K-N5-K

CADTyp souboruVelikost souboru
CAD Portal / CAD PortalLINK---
CAD-files 3-D / CAD-Dateien 3-DSTP989 KB
EPLAN
CAE EPLAN Data Portal / CAE EPLAN Data PortalLINK---
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZEDZ271 KB

Související produkty: NCN3-F31K-N5-K

Accessories

fa

fa

fa
fa

Our amplify article gives interesting insights about the development of the new, modern portfolio of inductive proximity sensors from Pepperl+Fuchs. Get the whole story here! 

 

 

Knowledge Base for Inductive Sensors

The knowledge base for inductive sensors contains extensive expertise and supports you in the highly precise and smooth operation of the sensors in your machinery and plants.

VariKont s technologií aktivního stínění

Indukční snímače VariKont s technologií aktivního stínění poskytují dlouhé spínací vzdálenosti bez ohledu na instalační situaci a okolní materiál. Profitujte z jednoduššího návrhu zařízení a snížených nákladů.

Indukční bezpečnostní senzory SIL 2 PL d

Vzhledem k tomu, že indukční bezpečnostní senzory SIL 2 / PL d nemají pásmo necitlivosti, může přenos dat probíhat bez zachování jakékoli minimální vzdálenosti mezi senzorem a cílem. Seznamte se s optimalizovaným portfoliem pro náročná prostředí.